info@potentiometer.co.in +91-9998700754

Linear position sensor

  • The Linear Non contact hall’s effect Displacement transducer is used to detect the displacement of system which correspondence to the Linear motion of the shaft of the sensor.
  • The Output signal correspondence to 0 to maximum stroke length with standard stroke length as 5mm,10mm, 20mm, 25mm and 30mm. Customization in the stroke length is possible.
  • Since the Product is based on Contactless Hall's effect Technology it has very long life.
  • Linear Hall effect transducer is a economical product with highly good accuracy and resolution of 12bit over a full range.
  • Variants
    • 12 bit resolution 5V input and 0.5 to 4.5Vdc Analog Ratio matric Output.
    • 12 bit resolution 24V input and 0 to 10Vdc / 4-20mA Analog Ratio matric Output.
    • 12 bit resolution +/- 15Vdc input and +/- 5Vdc output
    • 12 bit resolution PWM Output.
    • Hollow shaft, Shaft on both sides and Threaded shaft to have variable shaft tops available.
    • Metal housing of 18 X18 alluminum housing version available.
    • Spring Return and Non spring return version available.
    • Metal connector with IP protection possible
  • Benefits
    • Non Contact Linear Position Sensor based on Magnetic Technology.
    • Accurate Linearity upto 1% F.S. or 0.5% F.S (on request)
    • Extremely Long Life.
    • Extremely Compact in Size.
    • Short Circuit, Overvoltage and Reverse polarity protected.
  • Technical
  • Mechanical
  • Electrical
Technical

Mounting

For best performance of LHS-X-XX below points needs to be taken into consideration.
1) The Centering diameter of 8.1mm need to be perpendicular to the linear motion.
2) The PCD (pitch Circle Diameter to mount the sensor should be 33.5mm with a hole of 5mm dia.

Magnetic Cross Talk

If two LHS units are to be installed closer than 2 inch (measured between the center of both shaft), a magnetic shield, such as a small steel plate should be installed in between to prevent one from long with that a sensor from causing small changes  in reported  position through magnetic field cross talk.

Material

Component Material
Housing Glass Filled Nylon
Shaft Stainless

Temperature

Parameter Value
Operating Temperature -40 to 75 deg (standard)
-40 to 140 deg ( on request)
Storage Temperature -40 to 75 degC

Ordering Information

Mechanical

  Teflon wire Shielded Cable
Vsupply Red Brown
Ground Green Green
Voutput Yellow White

 

Stroke Length 5mm 10mm  20mm  25mm  30mm 
Parameters
A 42mm 42mm 42mm 55mm 55mm
B 12mm 17mm 27mm 36mm 39mm
Mechanical
Travel
7mm 12mm 21mm 27mm 34mm
Electrical
Travel
5mm 10mm 20mm 25mm 30mm
Resolution 1.25
micron
2.45
micron
4.9
micron
6.15
micron
7.35
micron

 

Parameters Range
Starting Torque  
Maximul Radial Load 1Kg.
Maximum Shaft Speed 100 Shaft Stroke / min
Bearing Life cycles 20 X 10^6 @rated radial Load
Weight of sensor  
Shaft Dia 5mm
Electrical
  • Electircal Analog Output
  • PWM O/P
Electircal Analog Output

 



Parameters Results
Supply Voltage (Vsupply) 5Vdc(+/- 10%) // 6 to 35Vdc
Supply Current 20mA // 50mA
Response time 50mS
Resolution 12bit @ full stroke
Load Resistance Minimum 10k ohms  (preferred >100k ohms)
Output (Voutput) 10% to 90% Vsupply (Ratiomatric) @ 5V supply
0.5 to 4.5Vdc @ 6 to 35Vdc supply.
Linearity 1% Independent Linearity ( Available 0.5% on request)
 
Signal Converter cards are available for 0 to 10Vdc, 4 to 20mA or any other digital communication protocol based on requirement.
 
 
PWM O/P

Parameter Results
Supply Voltage (Vsupply) 5Vdc (+/- 10%) // 6 to 35Vdc
Supply Current 20mA // 35mA
Frequency 200Hz, 500Hz, 1K Hz or 2 Khz based on requirement
Resolution 12bit
Output (Voutput) 0% to 90% duty Cycle
Linearity 1% Independent Linearity ( Available 0.5% on request)

 

Download Datasheet

Translate »